BTC Z22 Manuel d'utilisateur Page 8

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 64
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 7
Version 02.00, November 2014
8 Rohde & Schwarz R&S
®
BTC Broadcast Test Center
Measured maximum available output level versus frequency.
Level sweep
Operating mode
digital sweep in discrete steps
Trigger modes
free run
auto
execute one full sweep
single
execute one step
step
sweep start and stop controlled by
external trigger signal
start/stop
Trigger source
internal
external trigger signal (INST TRG A or B
at rear), rotary knob, touchpanel, remote
control
Trigger slope
external trigger signal
positive, negative
Sweep range
interruption-free level sweep,
level setting characteristic:
uninterrupted level setting
0.01 dB to 30 dB
Sweep shape
sawtooth, triangle
Step size setting resolution
0.01 dB
Dwell time setting range
1 ms to 10 s
Dwell time setting resolution
0.1 ms